INFUSION PUMP

Contract

Model: TOP2300

Producer : TOP- Japan

Factory : Meditop - Malaysia

Origin: Malaysia

4262 Viewed

FEATURES:

- Current speed range.

+ mL / hr (1mL / h increments).

1-999mL / h: TOP-H.

1-300mL / h: 20 drops / mL Standard IV set.

1-150mL / h: 60 drops / mL Standard IV set.

+ drops / minute (1mL / hour increments).

1-333 drops / minute: TOP-H.

1-100 drops / minute: 20 drops / mL Standard IV set.

1-150 drops / minute: 60 drops / mL Standard IV set.

+ Mode microphone (0.1mL / h increments): 0.1 - 99.9 mL / hr (TOP-H series IV set)

- Speed ​​of chasing air: Maximum speed of the set.

- KVO speed range.

+ Normal mode: 1-10 mL / hr (1mL / h increments).

+ Mode micro: 0.1 mL / hour (when set below 0.9mL / hour).

- Limited volume range.

+ Normal mode: 1-9999 mL (1 mL increments)

+ Microphone mode: 0.1 -999.9 mL (0.1 mL increments)

- Total volume range.

+ Normal mode: 0-9999 mL (1mL increments)

+ Microphone mode: 0.0 - 999.9 mL (0.1 mL increments)

- Accuracy of infusion mL / hour.

+ Normal mode: ± 5%: Select set of TOP-H series IV; ± 10%: Select a standard set of 20 drops / mL, 60 drops / mL.

+ Microphone mode: Select the set of TOP-H series IV: ± 5% (custom 1.0-99.9mL / hour); ± 10% (0.1-0.9 mL / h custom).

- Pressure detecting blockage.

+ 4 options (Select the IV series TOP-H).

P13: Under 150kPa Under 1100mmHg Under 1.5 kgf / cm2.

P12: Under 120kPa Under 900mmHg Under 1.2 kgf / cm2.

P11: Under 80kPa Under 600mmHg Under 0.8 kgf / cm2.

P12: Under 40kPa Under 300mmHg Under 0.4 kgf / cm2.

(When the flow rate is 0.9mL / h or less, the device operates P10).

+ 2 options (Select standard IV set of 20 drops / mL, 60 drops / mL).

P21: Under 150 kPa Under 1100mmHg Under 1.5 kgf / cm2.

P20: Under 80 kPa Under 600mmHg Under 0.8 kgf / cm2.

- In-line gas detection: 3 options.

Ar0: High Approximately 50µL.

Ar1: Average Approx. 0.1 mL / 15 minutes.

Ar2: Low Approximately 1mL / 15 minutes.

- When the flow rate is 10mL / h or less, the device operates Ar1 despite setting Ar2.

- Alarm: Internal air, Empty, Speed ​​error, Free flow, Fault wire IV, Clogging, Low battery, Auto power off, Battery connection, Battery problem, Door open, Dropping sensor, Reminder, Check setup, Complete infusion, Switch on power.

- AC power supply: AC 100-240V ± 10%; 50 / 60Hz.

- External DC power: DC 15V ± 10%.

- Internal battery: Rechargeable, DC 12V 1800 mAh Ni-MH (Model BP-23).

- Duration: Approximately 4 hours (At a rate of 25mL / h with a fully charged new battery).